Conduit rusted through

May 1, 2001
This conduit was completely rusted through, and the feeder conductors were still supplying a panelboard. The probable cause here may have been from the outside underground run where the rusted conduit allowed water to find its way into the raceway. In either case, the conduit will no longer provide the necessary protection to serve its intended purpose equipment grounding and protection against physical

This conduit was completely rusted through, and the feeder conductors were still supplying a panelboard. The probable cause here may have been from the outside underground run where the rusted conduit allowed water to find its way into the raceway. In either case, the conduit will no longer provide the necessary protection to serve its intended purpose — equipment grounding and protection against physical damage. I always call attention to the rule in Section 300-6. This section covers protection against corrosion for metal raceways, elbows, couplings, fittings, supports and support hardware and requires that they be of materials suitable for the environment in which they are to be installed. In Section 300-6, paragraph (a), a ferrous raceway is required to be suitably protected against corrosion inside and outside (except threads at joints) by a coating of approved corrosion resistant material such as zinc, cadmium or enamel. The exception “permits” threads at joints to be coated with an identified electrically conductive compound. Shouldn't this be a mandatory requirement instead of an exception?

About the Author

Joseph A. Tedesco

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.