A notched and botched gas and electric job

Sept. 1, 2002
Darryl Dempsey, an electrical inspector from Hillsborough County, Fla., said that the local gas company installed this gas line to supply a water heater in the garage of a new house under construction. They wanted to do a neat job, so they proceeded to install the gas line inside of the wall. Their only obstacle was a 2-in. rigid nonmetallic electrical conduit that ran from the meter socket enclosure

Darryl Dempsey, an electrical inspector from Hillsborough County, Fla., said that the local gas company installed this gas line to supply a water heater in the garage of a new house under construction. They wanted to do a neat job, so they proceeded to install the gas line inside of the wall. Their only obstacle was a 2-in. rigid nonmetallic electrical conduit that ran from the meter socket enclosure underground and up into the garage wall into the main electrical panel. They cut away a piece of the conduit to make room for the gas pipe so it would pass through to the water heater located on the other side of the panel. Keep in mind that the wiring was already in this conduit, so when it was cut, so were the cables inside. The electrical rough inspection previously passed inspection. I suppose the installer used the duct tape to pull the wires toward the front of the conduit to make a clear path for the gas pipe to pass through. It may also have been a feeble attempt to protect the already damaged wires.

Attention CEE News readers. Do you have a photo of a glaring Code violation?

E-mail your digital photos and descriptions to [email protected] or mail them to 350 North St., Boston, MA 02113. Your photo may be published in our upcoming photo gallery of America's worst NEC violations.

About the Author

Joe Tedesco

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.

8 Types of Electrical Conduit and Their Uses

Electrical conduit is a tube or raceway used to house and protect electrical wires within a building or structure. From data centers to underground subways to ports and bridges...