Still busted after all these years

Aug. 1, 2001
I found this raceway supplying a sign in front of a souvenir shop on the Las Vegas strip a few months ago. I took a photo of the same raceway about 10 years ago, and the raceway was damaged then as well. I think that the issue here is the so-called protection against physical (or is it physical?) damage that should be reconsidered by the installers. The circuit for the sign was pulled away exposing

I found this raceway supplying a sign in front of a souvenir shop on the Las Vegas strip a few months ago. I took a photo of the same raceway about 10 years ago, and the raceway was damaged then as well.

I think that the issue here is the so-called protection against physical (or is it “severe” physical?) damage that should be reconsidered by the installers. The circuit for the sign was pulled away exposing energized wires and without an equipment grounding conductor, either in the form of a conductor or proper connection. This violates Section 110-27(b). “Prevent Physical Damage. In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards shall be so arranged and of such strength as to prevent such damage.”

See also Sections 250-96(a), for proper bonding, and 300-10 for electrical continuity of metal raceways and enclosures. They are required to be metallically joined together into a continuous electric conductor and must be connected to all boxes, fittings and cabinets so as to provide effective electrical continuity.

I checked the sign later in the evening, and found it in operation. A note on the cover stated, “Please do not touch the box.”

About the Author

Joseph A. Tedesco

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.