Ecmweb 7068 408ecm18fig1a
Ecmweb 7068 408ecm18fig1a
Ecmweb 7068 408ecm18fig1a
Ecmweb 7068 408ecm18fig1a
Ecmweb 7068 408ecm18fig1a

Short Circuits

Aug. 1, 2004
Everyone makes mistakes. Some are just funnier than others.

Copy Shot

I was called to an automotive repair/body shop to install an outlet for a brand new copier. After scoping out the job, I found a subpanel 10 feet from the office where they wanted the outlet. I thought I'd install some pipe, wire, and the outlet and be out of there no problem. I finished cleaning up, but instead of grabbing my meter to prove my work, I just grabbed the cord and plugged in the machine to check for power. After the smoke cleared, I pulled out my meter and found there was 208V to neutral. It seems the electrician before me had fed the subpanel with the wild leg from the 3-phase, 120/240V delta panel. The only other circuits in the panel were a water heater and welder, so the wild leg had never shown up before. Thinking there was a neutral in the panel, I assumed that both legs were 120V. I hope someday I can meet the other electrician to see if he has an extra $1,300 to pay for that copier.
Doug Esser
Minnesota Lake, Minn.

Scare Tight

Years ago as an electrician for a major school district, I was working on a fire alarm system in an elementary school. While I was on-site, a staff member found me and excitedly said they needed my help — some children were trapped in a bathroom and couldn't get out. Sure enough, the door to a small bathroom on the second floor couldn't be opened by either the children stuck inside or the staff outside. It seems that someone had installed an exhaust fan through the bathroom wall, and it created a negative pressure that prevented the door from being opened. We couldn't locate the distribution panel that served the fan, and turning off circuits didn't help. So we decided to break out the lower panel on the door to relieve the vacuum. As soon as we did, the kids started climbing through the opening, heads and feet all at the same time.
Len Powell
Finksburg, Md.


Illustrations by Clint Metcalf

About the Author

EC&M Staff

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.