Code Quiz

Nov. 27, 2006
In a Class 1 location of a spray application (Art. 516) area, portable equipment such as portable electric lamps or other utilization equipment shall be permitted in which of the following situations?

Q. In a Class 1 location of a spray application (Art. 516) area, portable equipment such as portable electric lamps or other utilization equipment shall be permitted in which of the following situations?

A) Never permitted.
B) Portable electric lamps identified for Class 1, Division 1 or Class 1, Zone 1 locations where readily ignitable residues may be present. This is intended for operations in spaces not readily illuminated by fixed lighting within the spraying area.
C) Where portable electric drying apparatus is used in automobile refinishing spray booths, and the additional requirements of 516.4(D), Exception No. 2, (a) through (d) are met.
D) Both B and C.

Answer: D

Where necessary, and where in compliance with all of the requirements listed in 516.4(D), Exceptions No. 1 and No. 2, portable electric lamps or other utilization equipment shall be permitted to be used in a spray area during spray operations.

Owen is the owner and president of National Code Seminars and the holder of master electrician certifications in 46 states. He can be reached at [email protected].

About the Author

Steven Owen

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Strut Comparison Chart

Conduit support systems are an integral part of construction infrastructure. Compare steel, aluminum and fiberglass strut support systems.

Electrical Conduit for Bridges Guide

Learn about electrical conduit for bridge projects.

8 Types of Electrical Conduit and Their Uses

Electrical conduit is a tube or raceway used to house and protect electrical wires within a building or structure. From data centers to underground subways to ports and bridges...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...