What’s Wrong Here? Hint: If Two Is Company, and Three’s a Crowd — What’s 10?

Dec. 18, 2012
Can you identify the Code violation(s) in this photo?
How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Here’s your chance to moonlight as an electrical inspector and second-guess someone else’s work from the safety of your living room or office. Can you identify the Code violation(s) in this photo? Note: Submitted comments must include specific references from the 2011 NEC.

Hint: If two is company, and three’s a crowd — what’s 10?

‘Tell Them What They’ve Won...’

Using the 2011 NEC, correctly identify the Code violation(s) in this month’s photo — in 200 words or less — and you could win something to put in your tool­box. E-mail your response, including your name and mailing address, to [email protected], and Russ will select three winners (excluding manufacturers and prior winners) at random from the correct submissions. Note that submissions without an address will not be eligible to win. Winners will receive a fluorescent lighting tester from Milwaukee Tool, valued at $199. The product allows complete lamp, ballast, and pin testing, before or after install, without dismantling fixtures.

(*Please allow six to eight weeks for delivery of tools.)

October Winners

Our winners this month include: Thomas K. Heath, CHE director of facility operations for Sampson Regional Medical Center in Clinton, N.C.; Ronnie Measamer, physical plant director for Central Carolina Community College in Sanford, N.C.; and Dan Frohberg, an instructor for Northeast Community College in Norfolk, Neb. They all correctly identified the following violations with this crowded conduit body.

According to the general requirements in 314.16, boxes and conduit bodies must have sufficient size to provide free space for all enclosed conductors. More specifically, 314.16(C)(2) permits only conduit bodies that are “durably and legibly marked by the manufacturer with their volume to contain splices, taps, or devices.” The maximum number of conductors permitted is calculated in accordance with 314.16(B). As per 314.16(B)(1), “each conductor that originates outside the box and terminates or is spliced within the box is counted once.” This fitting contains two orange, two blue, two white, and two green 12 AWG wires for a total of eight 12 AWG wires. According to Table 314.16(B), 2.25 cubic inches are needed for each 12 AWG wire. Therefore, a minimum volume of 18 cubic inches would be needed, and this volume would need to be marked by the manufacturer on the conduit body in order for it to contain any splices. However, the conduit body in the photo is an “SLB.” According to 314.16(C)(3) [Short Radius Conduit Bodies], “Conduit bodies such as capped elbows and service-entrance elbows that enclose conductors 6 AWG or smaller, and are only intended to enable the installation of the raceway and the contained conductors, shall not contain splices, taps, or devices.”

About the Author

Russ LeBlanc | Owner

Russ started in the electrical trade as an apprentice in 1985. He worked his way up to become a Journeyman Electrician and then eventually became a Master Electrician and Licensed Construction Supervisor. In 1999 Russ become an Electrical Instructor for The Peterson School of Engineering in Massachusetts where he developed his passion for teaching, and quickly became Department Head of Electrical Instruction. Russ has taught thousands of apprentices, electricians, engineers, inspectors, and other electrical professionals during his career as an instructor. He continues to provide electrical professionals with Electrical Code seminars, Arc-Flash Awareness training seminars and educational material through his LeBlanc Consulting Services in North Reading, MA whose specialty is educating electricians. He has been an active member of the NFPA Electrical Section and has authored hundreds of National Electrical Code proposals and comments which have become Code rules to improve the safety for the electrical industry. Russ is also an IAEI certified Electrical Inspector.

Please visit www.russleblanc.net for more information.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.