What's Wrong Here? Hint: Approved for Outdoor Use

Feb. 16, 2012
Can you identify the Code violation(s) in this photo?

How well do you know the Code? Think you can spot violations the original installer either ignored or couldn't identify? Here's your chance to moonlight as an electrical inspector and second-guess someone else's work from the safety of your living room or office. It's your turn to identify the violation.

Hint: approved for outdoor use

Find the Answer

Joe Morren, a master electrician in Coopersville, Mich., ran across this installation when he was sent out to re-lamp an illuminated sign. "I'm not sure how this was overlooked by the maintenance department at the facility," says Morren. "The second photo with the dangling conductor and receptacle was adjacent to a busy walkway at the same facility."

Like many other photos we have received from our faithful readers over the years, these images show the dangers of potentially exposed and energized conductors. The lack of proper maintenance and repair is an ongoing concern — especially when equipment is obviously ignored for many years.

The dangling receptacle situation can be corrected rather easily by following the requirements outlined in 110.27, Guarding of Live Parts. More specifically, as per 110.27(A), "Except as elsewhere required or permitted by this Code, live parts of electrical equipment operating at 50V or more shall be guarded against accidental contact by approved enclosures."

Also, the cable assembly is probably not designed to be used in a wet location and would not comply with the wiring methods listed in Chapter 3.

> Try Another Quiz

About the Author

Joe Tedesco

Tedesco served the industry in many roles during his career. He was a director, senior electrical code instructor for National Technology Transfer, Inc. and American Trainco, Inc.. He was also a codes, standards and seminar specialist for the International Association of Electrical Inspectors and an electrical field service specialist for the National Fire Protection Association in Quincy, Mass. He ran his own business as an NEC consultant and is a Massachusetts licensed master electrician and journeyman electrician and certified electrical inspector (one and two family 2A; General 2B, and Plan Review, 2C). Tedesco also wrote articles for CEE News and EC&M (Code Violations Illustrated and What's Wrong Here?) for more than 15 years and helped launched the Moving Violations video series.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.