Receptacle Outlet for Peninsular Countertops

July 25, 2014
Receptacle outlets for countertop spaces shall be installed in accordance with 210.52(C)(1) through (C)(5).

In dwelling units, at least one receptacle outlet shall be installed at each peninsular countertop having a long dimension of _____ in. or greater, and a short dimension of _____ in. or greater.

a) 12, 24
b) 24, 12
c) 24, 48
d) 48, 24

See answer and applicable Code reference

The correct answer is: b) 24, 12

Part III of Art. 210 of the NEC outlines the requirements for required outlets on branch circuits. Receptacle outlets for countertop spaces shall be installed in accordance with 210.52(C)(1) through (C)(5).

As per 210.52(C)(3), "At least one receptacle outlet shall be installed at each peninsular countertop space with a long dimension of 24 in. or greater and a short dimension of 12 in. or greater. A peninsular countertop is measured from the connecting edge."

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations

Electrical Conduit Comparison Chart

CHAMPION FIBERGLASS electrical conduit is a lightweight, durable option that provides lasting savings when compared to other materials. Compare electrical conduit types including...

Fiberglass Electrical Conduit Chemical Resistance Chart

This information is provided solely as a guide since it is impossible to anticipate all individual site conditions. For specific applications which are not covered in this guide...

Considerations for Direct Burial Conduit

Installation type plays a key role in the type of conduit selected for electrical systems in industrial construction projects. Above ground, below ground, direct buried, encased...

How to Calculate Labor Costs

Most important to accurately estimating labor costs is knowing the approximate hours required for project completion. Learn how to calculate electrical labor cost.