| | | | | | In this Moving Violations, Russ examines an exit sign with a few issues. Take a look at the wiring. The power supply cord is hung and secured on the wall, which violates Sec. 400.12 that prohibits the cord from being used in such a manner. Also, there is a violation of Sec. 700.12(H)(2) due to the length of the cord exceeding 3 ft. |
|
|
|
| |
|
|
|
| | Sponsored | | Utility projects can be complex with challenging underground installation. In the Utility Solutions Guide, learn more about how BABA-compliant fiberglass conduit, elbows, utility risers, and interference gasket conduit provide solutions to common utility challenges. |
|
|
|
| |
|
|
|
| | | | Can Type SO cord be used to supply a receptacle located flush within a wall? |
|
|
|
| |
|
|
|
| | Sponsored | | Cabinet Cooler Systems stop electronic control downtime due to heat, dirt & moisture. They produce 20 degree Fahrenheit air from ordinary compressed air. Thermostat control minimizes air usage. Maintains the NEMA 4, 4X and 12 rating of the enclosure. |
|
|
|
| |
|
|
|
| | | | See the latest Code violations from NEC Consultant Russ LeBlanc. This installment features a shock hazard at a parking lot pole light and some scary fountain wiring. |
|
|
|
| |
|
|
|
| | | | Correctly implementing conductor requirements involves more than just looking something up in a table. |
|
|
|
| |
|
|
|
| | | | Do you want to join Trevor and share what a day in the life looks like for you? We’re looking for more “Everyday Electricians” who work in other market sectors to showcase the unique and diverse work EC&M’s audience tackles on a daily basis. So, no matter what electrical niche you specialize in, we’d like to hear from you — the goal is sharing educational... |
|
|
|
| |
|
|
|
| | | Fill in the blank. Article 348 covers the use, installation, and construction specifications for flexible metal conduit (FMC) and associated _____. |
|
|
|
| |
| | | Prior to 2008, communications outlets were not required to be installed in dwelling units. However, a proposal was submitted for the 2008 Code to require a minimum of two communications outlets for newly constructed dwelling units. CMP 16 accepted this proposal in principle with new Sec. 800.156 which stated, “For new construction, a minimum of one... |
|
|
|
| |
|
|
|
| | | Fill in the blank. Underground _____ shall be installed so they are accessible without excavating sidewalks, paving, earth, or other substance that is to be used to establish the finished grade. |
|
|
|
| |
| | | With advancements in LED technology and control systems, emergency lighting is becoming more integrated with overall building automation systems. This integration offers greater flexibility, efficiency, and enhanced safety. By understanding the complexities of emergency lighting and adhering to relevant codes and standards, building owners and designers... |
|
|
|
| |
|
|
|
| | | How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Hint: Rigid PVC conduit gone wrong. |
|
|
|
| |
| | | Fill in the blank. Threadless couplings and connectors used with RMC buried in masonry or concrete shall be the _____ type. |
|
|
|
| |
|
|
|
| | |
|
| | |
|