| | | | | | How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Hint: EMT is never enough. |
|
|
|
| |
|
|
|
| | Sponsored | | Uneven ground, shifting soil, and freeze/thaw cycles can complicate utility installations. New Champion Fiberglass® Expandable Utility Risers (patent pending) adapt on-site with height adjustability, no cutting, and resistance to extreme conditions. |
|
|
|
| |
|
|
|
| | | | Fill in the blank. The upper end of the rod electrode shall be _____ ground level unless the aboveground end and the grounding electrode conductor attachment are protected against physical damage as specified in 250.10. |
|
|
|
| |
|
|
|
| | Sponsored | | The M18 FUEL Overhead Rotary Hammer w Integrated Dust Extraction is a new-to-world solution optimized for ceiling drilling. The 2-in-1 design delivers improved ergonomics for overhead work compared to traditional rotary hammer & dust extractor attachments, while maintaining Table 1 compliance. The built-in dust extractor creates a compact, lightweight tool with optimized balance for less fatigue. |
|
|
|
| |
|
|
|
| | | | In this episode of EC&M Code Conversations, Editor-in-Chief Ellen Parson and Code Consultant Russ LeBlanc discuss the Sec. 314.29 requirements regarding LB type conduit bodies and where confusion can creep in. |
|
|
|
| |
|
|
|
| | | Article 110 provides general requirements for all installations. Circuit protective devices need to clear a fault without extensive damage to the electrical equipment of the circuit. |
|
|
|
| |
| | Sponsored | Simplify your installations with Southwire MCAP® Cable. Our free MCAP® Cable Cost Calculator demonstrates how you can eliminate unnecessary steps, reduce labor, and meet compliance requirements—all while enhancing jobsite efficiency. |
|
|
|
| |
|
|
|
| | | Fill in the blank. An outdoor receptacle in a location protected from the weather shall be installed in an enclosure that is weatherproof when the receptacle is _____. |
|
|
|
| |
| | | The National Fire Protection Association (NFPA) recently announced that the Kentucky Association of Electrical Inspectors is the latest Electrical Inspection Section Affiliate Chapter (EIS). As an NFPA EIS Affiliate Chapter, the Kentucky Association of Electrical Inspectors will serve as a key resource for the state’s electrical inspection community... |
|
|
|
| |
|
|
|
| | | With the rise of Artificial Intelligence (AI), data center demand has increased exponentially. Test your knowledge about data centers and enter for a chance to win a $25 gift card to Amazon! |
|
|
|
| |
| | | Whether located inside or outdoors, premises wiring systems powered by an electric utility have what is known as an electrical service. It is the portion of the electrical system from the utility-defined point of connection to the input terminals of the main overcurrent device — although strictly speaking (not included in this definition), the entrance... |
|
|
|
| |
|
|
|
| | | Check out this raceway. LED rope lighting is attached to the raceway with cable ties. At several places along the raceway, the cable ties securing the lighting have broken and left it dangling. This installation is a violation of Sec. 300.11(C). |
|
|
|
| |
| | | In a dwelling unit kitchen, can a receptacle serving a counter space be located below the countertop? |
|
|
|
| |
|
|
|
| | |
|
| | |
|