• Installing Type AC Cable in Accessible Attic Spaces

    Article 320 covers the use, installation, and construction specifications for armored cable, Type AC.
    July 3, 2014

    When Type AC cable is run across the top of a floor joist in an attic without permanent ladders or stairs, substantial guard strips within _____ of the scuttle hole, or attic entrance, shall protect the cable.

    a) 3 ft
    b) 4 ft
    c) 5 ft
    d) 6 ft

    See answer and applicable Code reference

    The correct answer is: d) 6 ft

    Article 320 covers the use, installation, and construction specifications for armored cable, Type AC. As noted in 320.23(A), "Where run across the top of floor joists, or within 7 ft of the floor or floor joists across the face of rafters or studding, the cable shall be protected by substantial guard strips that are at least as high as the cable. Where this space is not accessible by permanent stairs or ladders, protection shall only be required within 6 ft of the nearest edge of the scuttle hole or attic entrance."