Code Quiz: Receptacles in Dwelling Unit Garages

May 18, 2023
Test your knowledge of the NEC with this challenging question.

Based on the 2023 NEC.

Question: True or false? All receptacles in dwelling unit garages must be supplied from 20A branch circuits.

See answer below.

Answer: False

Explanation: In the 2023 NEC, text was added to Sec. 210.11(C)(4) to make it clear that receptacles installed in addition to those required by Sec. 210.52(G)(1) can be fed from 15A branch circuits. Only those receptacles required by Sec. 210.52(G)(1) are required to be on 20A branch circuits.

Lupacchino is a senior design engineer with Gaylor Electric, Inc. in Noblesville, Ind. and serves as an alternate on NEC Code-Making Panel No. 3. He is currently licensed in more than 80 jurisdictions. He can be reached at [email protected]

About the Author

John Lupacchino | Senior Design Engineer

John began his career in electrical construction as an apprentice and worked his way through the trade. He is currently licensed in more than 80 jurisdictions. With more than 35 years of experience, he now plays a vital role in Gaylor Electric’s Engineering Department, where he serves as a senior design engineer. With a focus on design engineering, quality assurance, and code compliance, he has earned the highest level of respect from industry professionals alike. John currently serves as an alternate on NFPA 70 Code Making Panel No. 3. In addition, he enjoys sharing his electrical knowledge through education. As an Associated Builders and Contractors instructor, he continues to help grow a new generation of high-performing construction leaders.

Voice your opinion!

To join the conversation, and become an exclusive member of EC&M, create an account today!

Sponsored Recommendations