| | | | | | For this episode of Moving Violations, Russ highlights an EMT installation without any clips or support, a violation of Sec. 358.30. There’s also no support on a long run of LFMC, which is a violation of Sec. 350.30. Finally, there is a dangling box which violates Sec. 314.23. Do you see anything else in the video that needs to be addressed in order... |
|
|
|
| |
|
|
|
| | Sponsored | | Commercial and industrial projects don't fit catalog equipment. IEM builds custom switchgear, switchboards, substations, panelboards, enclosures, ATS, PDUs, RPPs, and more, engineered to your spec with lead times that hold. We're North America's largest independent custom power distribution manufacturer. In-house field service for installation, commissioning, and maintenance. |
|
|
|
| |
|
|
|
| | | | True or false? A fire pump feeder may be routed inside a building where it is encased in 2 in. of concrete. |
|
|
|
| |
|
|
|
| | Sponsored | | Beat the summer time heat and prevent hot weather failures. Cabinet Cooler® Systems produce 20 degree F air from an supply of compressed air to cool electrical controls. Thermostat control minimizes air usage. NEMA 4, 4X, 12 and Hazardous Location. |
|
|
|
| |
|
|
|
| | | | In this episode of EC&M Code Conversations, Editor-in-Chief Ellen Parson and Code Consultant Russ LeBlanc discuss 2026 NEC changes related to an expanded requirement regarding arc flash hazard marking in other than dwelling units. Russ explains the major expansion to Sec. 110.16 and what changed with the arc-flash labeling requirements. He also explains... |
|
|
|
| |
|
|
|
| | Sponsored | | Workplace Safety Academy is an online resource hub built to help teams stay ahead of risk with guidance on prevention, readiness and safer day-to-day work. |
|
|
|
| |
|
|
|
| | | Article 200 provides the requirements for the use and identification of grounded conductors. As with most NEC articles, it has its own general requirements. Unlike the arrangement in many articles, those do not consist of Part I. Article 200 does not have “Parts.” The general requirements are in Sec. 200.4. |
|
|
|
| |
| | | Fill in the blank. Where multiple services supply portable structures at carnivals, the equipment grounding conductors that serve structures separated by less than _____ shall be bonded together at the portable structures. |
|
|
|
| |
|
|
|
| | | Welcome to this EC&M Tech Talk covering Art. 706 Energy Storage Systems (ESSs) found in the 2026 National Electrical Code. Randy Barnett takes us through an explanation of what constitutes an energy storage system and different types of energy storage systems. From this introduction a review is conducted of all six parts of Art. 706. |
|
|
|
| |
| | Sponsored | Stack Caddy™ is a stackable modular storage system built for electricians who need small parts, tape, bits, fasteners, and jobsite essentials organized and ready to grab. Explore the full line, including Panel Caddy™ Tool Deck, Panel Caddy™ T-Bone, Wirenut Koozie™, Drill Bit Holder, Wirenut Storage Buddy™, and Inspector Series Caddy™. |
|
|
|
| |
|
|
|
| | | How well do you know the Code? Think you can spot violations the original installer either ignored or couldn’t identify? Hint: Wrong choice of wiring methods. |
|
|
|
| |
| | | Fill in the blank. Noncombustible surfaces that are broken or incomplete shall be repaired so there will be no gaps or open spaces greater than _____ in. at the edge of a cabinet or cutout box employing a flush-type cover. |
|
|
|
| |
|
|
|
| | |
|
| | |
|